Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report
Dong Yeong Lee, Sun Chul Hwang, Dae Cheol Nam, Jin Sung Park
Department of Orthopaedic Surgery, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju, Korea. jsparkler@naver.com
Received: 1 August 2015   • Revised: 29 August 2015   • Accepted: 31 August 2015
Abstract
Acute ruptures of flexor tendons in patients with distal radius fractures are very rare complications. The majority of reported cases, flexor tendon rupture associated with distal radius fracture, is chronic flexor tendon ruptures, which are caused by implants for fixation or rough surfaces of malunited distal radius. We experienced an unusual case of an acute rupture of the flexor digitorum profundus tendon in a patient with a distal radius fracture, in addition to providing an auxiliary review of the literature.
 


About
Article and topics
Article category

Browse all articles >

Topics

Browse all articles >

Browse articles
Editorial policies
For contributors
Editorial Office
St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, 93 Ji-dong, Paldal-gu, Suwon 16247, Korea
Tel: +82-31-249-7186    Fax: +82-31-254-7186    E-mail: journal@handmicro.org                

Copyright © 2024 by Korean Society for Surgery of the Hand, Korean Society for Microsurgery, and Korean Society for Surgery of the Peripheral Nerve.

Developed in M2PI

Close layer
prev next